产品列表PRODUCTS LIST

首页>产品中心>日本光明北川式气体检测管>气体快速检测管>100一氧化碳CO气体检测管100 Carbon monoxide 5-1000ppm

一氧化碳CO气体检测管100 Carbon monoxide 5-1000ppm

简要描述:

一氧化碳CO气体检测管100 Carbon monoxide 5-1000ppm,反应可分为两种,一种是被检测气体与检测试剂直接发生反应,产生变色。另一种是将被测气体转变为其他气体,转变后的气体再与检测试剂反应,产生变色。

更新时间:2024-04-24

发邮件给我们:554328895@qq.com

分享到: 1
在线留言
一氧化碳CO气体检测管100 Carbon monoxide 5-1000ppm

一氧化碳CO气体检测管100 Carbon monoxide 5-1000ppm

Tube No.
1. PERFORMANCE
1) Measuring range :25-1,000 ppm 5-300 ppm
Number of pump strokes 1(100ml) 3(300ml)
2) Sampling time :3 minutes/1 pump stroke
3) Detectable limit :1 ppm(300mr)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Concentration chart method
7) Colour change :Yellow→Dark brown
2. RELATIVE STANDARD DEVIATION
RSD-low:5% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
Pottasium disulphate palladate(II)is reduced, and Palladium is liberated.
CO+K2Pd(SO3)2→K2(SO3)2PdCO
K2(SO3)2PdCO→CO2+SO2+Pd+K2SO3
4. CALIBRATION OF THE TUBE
STANDARD GAS CYLINDER METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
100 CARBON MONOXIDE
Substance ppm Interference ppm Coexistence
Ethylene 5,000 Pale grey stain is produced. 5,000 The top of discoloured layerbecomes
unclear and higher readings are given.
Whole layer is discoloured to Greyish
Hydrogen 5,000 Greyish yellow stain is produced. 5,000 yellow and the top of discoloured layer
becomes unclear.
Acetylene 1.5 Dark green stain isproduced. C×O c1o/n5c. Higher readings are given.
Sulphur dioxide 100 Original colour is faded. 〃〃
Nitrogen dioxide Tafhfeec atecdc.uracy of readings is not 〃〃
TEMPERATURE CORRECTION TABLE
Chart Correct Concentration (ppm)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(ppm) (32°F) (50°F) (68°F) (86°F) (104°F)
1,000 870 930 1,000 1,030 1,060
900 780 840 900 930 960
800 690 750 800 830 850
700 610 660 700 720 740
600 520 560 600 620 640
500 430 470 500 520 540
400 350 370 400 410 430
300 260 280 300 310 320
200 180 190 200 210 220
100 90 100 100 100 110
X
1000
900
800
700
600
500
400
300
200
100
50
0
25
X
1000
900
800
700
600
500
400
300
200
100
50
0
25
CARBON MONOXIDE�
LENGTH-OF-STAIN�

FOR 1 PUMP STROKE(100ml)�
ppm IN AIR CONCENTRATION
www.r-biopharm.com.cn