产品列表PRODUCTS LIST

首页>产品中心>日本光明北川式气体检测管>气体快速检测管>105SD戊胺CH3(CH2)3CH2NH2气体检测管105SD PENTYL AMINE 2-22ppm

戊胺CH3(CH2)3CH2NH2气体检测管105SD PENTYL AMINE 2-22ppm

简要描述:

戊胺CH3(CH2)3CH2NH2气体检测管105SD PENTYL AMINE 2-22ppm,通过直接读取方式,可简单测定空气中各种气体的浓度。使用1个检测器(泵),只要更换检测管,就能进行测定。由于是直接读取式,所以不会出现人为误差。1冲程(100ml)30~120秒,就可以结束浓度测定。

更新时间:2024-04-24

发邮件给我们:554328895@qq.com

分享到: 1
在线留言
戊胺CH3(CH2)3CH2NH2气体检测管105SD PENTYL AMINE 2-22ppm

戊胺CH3(CH2)3CH2NH2气体检测管105SD PENTYL AMINE 2-22ppm

Tube 05SD
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes

The KITAGAWA Gas Detector Tube System is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The KITAGAWA Gas Detector Tube System is comprised of an Air Sampling Pump and Precision Gas Detector Tubes.

The KITAGAWA air sampling pump reproducibly draws 100cc of sample air through the detector tube. All detector tubes are calibrated for a single pump stroke; there is no need for multiple volumes or stroke counters.

Each detector tube is formulated with high purity reagents that absorb and react with the target gas or vapour being measured. A colorimetric stain is created that is proportional in length to the concentration. For most tubes, the concentration is read directly off the measurement scale on each tube. 
 How To Use The KITAGAWA Gas Detector Tube System 
 
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.

For specific information, please refer to the list of detector tubes.