产品列表PRODUCTS LIST
汞蒸气Hg气体检测管142S MERCURY VAPOUR 0.1-10mg/m3,汞为银白色的液态金属,常温中即有蒸发。汞中毒(mercurypoisoning)以慢性为多见,主要发生在生产活动中,长期吸入汞蒸气和汞化合物粉尘所致。以精神-神经异常、齿龈炎、震颤为主要症状。大剂量汞蒸气吸入或汞化合物摄入即发生急性汞中毒。对汞过敏者,即使局部涂沫汞油基质制剂,亦可发生中毒。接触汞机会较多的有汞矿开采,汞合金冶炼,金和银提取,汞整流器,以及真空泵、照明灯、仪表、温度计、补牙汞合金、雷汞、颜料、制药
更新时间:2024-11-07
在线留言汞蒸气Hg气体检测管142S MERCURY VAPOUR 0.1-10mg/m3
Tube 42S
1. PERFORMANCE
1) Measuring range :0.5-10mg/m3 0.1-2.0mg/m3
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :5 minutes /5 pump strokes
3) Detectable limit :0.02 mg/m3(500ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 5 pump strokes
7) Colour change :Grey→Pale orange
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By reacting with Cupric iodide(II), Cupric mercury iodide is produced.
Hg+CuI→Cu2(HgI4)
4. CALIBRATION OF THE TUBE
VAPOUR PRESSURE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
mg/m2
0.1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
GAS To pump
142S MERCURY VAPOUR
Substance Interference ppm Coexistence
Chlorine The accuracy of readings is not affected. 0.1 Lower readings are given.
Hydrogen chloride 〃0.5 〃
Nitrogen dioxide Brown stain is produced. 0.1 〃
Hydrogen Sulphide 〃0.5 〃
(NOTE)
In case of 1 pump stroke, actual concentration is calculated with five times of reading value.