产品列表PRODUCTS LIST
丙烯酸乙酯CH2=CHCO2C2H5气体检测管211U ETHYL ACRYLATE 5-60ppm (+) 检测剂是将某些能与待测物质发生化学反应并可改变颜色的化学试剂吸附在固体载体颗粒表面上加工而得,如硫化氢检测管,其反应原理如下∶H2S+Pb(AC)2 PbS↓+2HAC
更新时间:2024-04-17
在线留言丙烯酸乙酯CH2=CHCO2C2H5气体检测管211U ETHYL ACRYLATE 5-60ppm
Tube No.211U
1. PERFORMANCE
1) Measuring range :5-60 ppm
Number of pump strokes 2(200ml)
2) Sampling time :3 minutes/2 pump strokes
3) Detectable limit :0.5 ppm
4) Shelf life : :2 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Graduations printed on the tube are calibrated by Methyl acrylate at 2 pump strokes
and Ethyl acrylate concentration is determined by using a conversion chart.
8) Colour change :Yellow→Pale blue
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
Chromium oxide is reduced.
CH2=CHCO2CH2CH3+Cr6++H2SO4→Cr3+
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
60
40
20
10
5
ppm
200ml
DEHUMIDIFIER
(White)
211U C ETHYL ACRYLATE
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(ppm) (32°F) (50°F) (68°F) (86°F) (104°F)
60 80 70 60 52 44
40 52 46 40 34 28
20 27 23 20 17 15
10 14 12 10 9 7
5 7 6 5 4 3
Substance Interference Coexistence
Alcohols Similar stain is produced. Higher reading are given.
Paraffin (morefi nth haynd Cro3c)arbons DWahrokl e b rreoawgne.nt is discoloured to 〃
Halogenated hydrocarbons 〃〃
Esters 〃〃
Aromatic hydrocarbons FIG.1,2 〃〃
0
20
30
10
50
60
40
80
100
90
70
Toluene〔ppm〕�
FIG.1 Influence of Toluene
Ethyl acrylate
indicating value 〔ppm〕
10 20 30 40 50 0
20
30
10
50
60
40
80
100
90
70
Hexane〔ppm〕�
FIG.2 Influence of Hexane
Ethyl acrylate
indicating value 〔ppm〕
100200300400500600700
Ethyl Acrylate(ppm)�
No.211U Tube reading(ppm)�
(200mR)�
5
10
20
40
60
5
10
20
40
60
上一篇:111U乙酸乙酯气体检知管 111U ETHYL ACETATE CH3CO2C2H5 10-1000ppm
下一篇:104SA酒精(乙醇)C2H5OH气体检测管104SA ETHYL ALCOHOL(ETHANOL)
返回列表>>相关产品